IND Enabling Studies – Nonclinical GLP Safety Assessments
GLP/GMP-certified preclinical safety studies for your IND submission
Performing GLP Studies with InnoSer’s Support
Good Laboratory Practice (GLP) defines the quality standards required to ensure that your nonclinical safety studies are reliable, traceable and suitable for regulatory submission. However, GLP guidelines do not determine which studies should be performed. The appropriate study design depends on the therapeutic modality, mechanism of action, intended clinical use and regulatory requirements.
As a specialist preclinical CRO, InnoSer supports sponsors in designing and executing GLP toxicology programmes tailored to their specific development needs. By combining expertise in exploratory pharmacology, translational models, immunotoxicology and GLP toxicology, we help you identify the most relevant test systems and endpoints to generate meaningful safety data.
Our GLP capabilities support a wide range of therapeutic modalities, including small molecules, biologics, RNA therapeutics, cell and gene therapies. Study designs may include repeated-dose toxicity, safety pharmacology, immunotoxicity assessment, immunogenicity testing, biodistribution studies and other modality-specific non-clinical safety evaluations.
✓ GLP-certified since 2004: GLP toxicology studies and immunotoxicology/immunogenicity assessments
✓ GMP certified since 2007: in vivo adventitious virus testing & potency testing of recombinant vaccines
✓ 25 years of preclinical safety expertise: founded 2001 · EU-based · Gronau, Germany
✓ OECD · ICH S6 · ICH S8 · ISO 10993 · EMA/FDA aligned
✓ 2 GxP archives · full audit trail · client audit rights
Guesswork slows down IND submissions. GLP-compliant nonclinical safety data, tailored to your program, keeps things moving.
COLLABORATIVE SCIENTIFIC GUIDANCE
Work directly with experienced toxicologists and study directors throughout planning, execution, and reporting.
TAILORED STUDY DESIGN
No one-size-fits-all approach. Study strategies are adapted to your molecule, mechanism of action, and development stage.
AGILE SUPPORT FROM EXPLORATORY TO GLP
Integrate existing pharmacology data and translational insights to build efficient safety packages and avoid unnecessary studies.
What studies does InnoSer offer under GLP/GMP?
Chemical testing in accordance with OECD guidelines
- OECD 417 – Toxicokinetic
- OECD 402 – Acute Dermal Toxicity
- OECD 420 – Acute Oral Toxicity – Fixed Dose Procedure
- OECD 423 – Acute Oral toxicity – Acute Toxic Class Method
- OECD 425– Acute Oral toxicity – Up and Down Procedure
- OECD 407 – Repeated Dose 28-day Oral Toxicity Study in Rodents
- OECD 408 – Repeated Dose 90-Day Oral Toxicity Study in Rodents
- OECD 410 – Repeated Dose Dermal Toxicity: 21/28-day Study
- OECD 411 – Subchronic Dermal Toxicity: 90-day Study
- OECD 452 – Chronic Toxicity Studies
- OECD 453 – Combined Chronic Toxicity/Carcinogenicity Studies
- OECD 451 – Carcinogenicity Studies
- OECD 414 – Prenatal Development Toxicity Study
- OECD 416 – Two-Generation Reproduction Toxicity
- OECD 421 – Reproduction/Developmental Toxicity Screening Test
- OECD 422 – Combined Repeated Dose Toxicity Study with the Reproduction/Developmental Toxicity Screening Test
- OECD 443- Extended One-Generation Reproductive Toxicity Study
- OECD 442 B – Skin Sensitization
- OECD 474: Mammalian Erythrocyte Micronucleus Test
Medical Device testing in accordance with ISO10993 guidelines
- ISO10993-1 Requirements and general principles for the evaluation of biological safety within a risk management process
- ISO10993-2: Animal welfare requirements
- ISO10993-12: Sample preparation and reference materials.
- Under consideration of ISO10993-17: Toxicological risk assessment of medical device constituents
- ISO10993-18: Chemical characterization of medical device materials within a risk management process
- ISO/TR10993-19: Nano-technologies – Considerations for performing toxicokinetic studies with nanomaterials, etc.
Food testing in accordance with EFSA guidelines for novel foods and ingredients, food additives and flavourings, food contact materials
- Toxicology testing in accordance with EFSA and OECD guidance documents
- Repeated dose administrations via oral gavage or feed
(Bio)Pharmaceuticals (EMA) - Testings in accordance with ICH M3 (R2) and ICH S6 (Biotechnological Products)
- Local tolerance
- Carcinogenicity (S1)
- Toxicokinetics & Pharmacokinetics (S3)
- Toxicity testing (S4), Repeated Dose Toxicity
- Reprotoxicity (S5)
- Immunotoxicology Studies (S8)
- Non-clinical Biodistribution considerations for Gene therapy products (S12)
- Immunology assays: in vivo, TDAR assay (KLH), Delayed type hypersensitivity, Sensitization (mLLNA)
- Autoimmunity studies
- Tumorigenicity/ oncogenicity
- Vaccine studies
- Potency assays/ efficacy studies
- Histopathology of Immune organs
- Differential blood counts
- ex-vivo/ in vitro Immunophenotyping (FC) of leucocytes and lymphocytes, Cytokine release (FC, CBA), NK-activity ex vivo and following in vitro stimulation
- Antigen dependent T-cell proliferation (ELISPOT)
- Mitogen dependent proliferation (BrdU)
- Phagocytosis of macrophages from peritoneal exudates
- Complement activation (MAC, CARPA, ELISA)
- Serological quantification of antibody concentrations/ isotype distribution
- Pharmacological in vitro studies
- Pharmacokinetics of biologicals (direct / biomarkers)
- Anti-drug antibody assays (screening / confirmatory ADA)
- Immunohistological analytics
- Detection of specific antigens in selected tissues
- Enzyme-linked detection systems
- Semi-quantitative analysis and analytics of IHC
- in vivo analysis for adventitious viruses in accordance with European Pharmacopoeia 2.6.16 (Ph.Eur.), ICH guideline Q5A (CPMP/ICH/295/95) Points to Consider PTC (1993)
Every molecule is different. Your GLP strategy should be too.
当社のチームと協力し、精密かつ専門的な知見をもって、貴社の薬剤と治療標的の効果を評価します
あなたの研究を支える人々

Dr. Marion Hecht, PhD
Director of Operations, InnoSer Deutschland
InnoSerの最新研究を発見する
医薬品開発パイプラインのナビゲーション
AAALAC認定
InnoSerはAAALAC認証を取得し、責任ある動物ケアと利用への取り組みを実証しています。AAALAC Internationalは、自主的な認証および評価プログラムを通じて科学における動物の適切な扱いを推進する非営利組織です。InnoSerのオランダおよびベルギー施設は、それぞれ2016年および2020年よりAAALAC認証を取得しています。AAALAC認証プログラムの詳細はこちらをご覧ください。
![]()
動物福祉
3R原則は、政策や規制の変更から新技術・手法の開発と普及に至るまで、あらゆる分野に影響を及ぼします。このためInnoSerは、これらのプロセスに対する継続的な取り組みと監視を実施しています。当社が実践する手順は、動物実験の代替・削減・改善を最大限に実現し、研究および医薬品開発におけるこれらの原則への取り組みを促進します。
info@innoserlaboratories.com

![Cognitive profiling in the APP[V717I]xTau[P301S] mouse model](https://www.innoserlaboratories.com/wp-content/uploads/2026/07/Figure-1-MWM.png)
![トランスレーショナル神経科学:Tau[P301S]を保有する雌マウスと雄マウスの包括的な縦断的プロファイリング](https://www.innoserlaboratories.com/wp-content/uploads/2026/06/Female-TauP301S-mice-show-early-spontaneous-hyperactivity-in-automated-home-cages-PhenoTyperTM-229375_1080x323.png)
